Material data
| METRIC | IMPERIAL | |||
| Property | Unit | Result | Unit | Result |
| Basis Weight (Average) | g/m² | 65.2 | oz/yd² | 2.2 |
| Thickness | µm | 240-280 | mils | 10.25 |
| Breaking Strength Grab MD | N | 107.9 | lbs | 24 |
| Breaking Strength Grab CD | N | 54.8 | lbs | 12.14 |
| Tearing Strength Trapezoid MD | N | 62.6 | lbs | 14.07 |
| Tearing Strength Trapezoid CD | N | 31.0 | lbs | 6.96 |
| Tensile Strength at Break MD | g/25mm | 4800 | oz/in | 172 |
| Tensile Strength at Break CD | g/25mm | 2850 | oz/in | 102.13 |
| Elongation at Break MD % | % | 80 | % | 80 |
| Elongation at Break CD % | % | 84 | % | 84 |
| WVTR | g/m² /24hrs | 2966 | oz/yd²/24hr | 87.46 |
| Surface Resistivity EN1149 | Ω | 1.4x1010 | - | - |
| Burst Resistance ISO2960/1974 | kPa | 180 | - | - |
| Abrasion Resistance EN530 | # of cycles | >100 | # of cycles | >100 |
| Flex Cracking Resistance ISO7854 | # of cycles | >100,000 | # of cycles | >100,000 |
| Chemical Repellency | Penetration | Repelled |
| Sulphuric Acid 30% | 0 | 98.0 |
| Sodium Hydrozide 10% | 0 | 98.4 |
| Isopropanol (Alcohol) | 0 | 96.9 |
| Water & Detergent | 0 | 99.5 |
| Xylene (Undiluted) | 0 | 91.8 |
| Butan-1 (Undiluted) | 0 | 93.8 |
| Lissapol | 0 | 95.5 |
| Hydrochloric Acid 35% | 0 | 97.8 |
| Gasoline | 0 | 86.0 |
| Motor Oil | 0 | 91.8 |
| Trichloroethylene | 0 | 93.1 |
| Acetic Acid | 0 | 98.7 |
Flammability: Class 1
This particular classification (under 16CFR 1610) and our certification under EN13274-4 method 3, resistance to ignition are both recognised under ISO 6941-2003 as representing similar performance minimum requirements. CovTech™ 365PHE results "show No drop formation (fusing), is self-extinguishing and has a after-flame time of <5 seconds.
"CovTech™ is not flame resistant and should not be worn near hot surfaces, 
flame and spark generating processes"
Surface resistivity – ASTM D257
This particular ASTM reference to fabric surface resistivity performance (fabric antistatic capability) now references EN1149-1 anti-static performance requirements. CovTech™ 365PHE was tested to EN1149-1.
This technical data provided within is based on laboratory test performance criteria performed under controlled conditions.
It is the responsibility of the user of these garments to ascertain the level of exposure of the hazard and the selection of the correct personal protective equipment required for his or her application.
GSSM and its distributors assume no obligation or liability in the improper use of CovTech™ Protective Coveralls.
CovTech™ — Distributing globally
GSSM co-operates with distributors across the globe, to bring our safety solutions to you.
We are currently distributing to:

Home | CovTech | Technology | Distributor zone | Become a distributor | Company | Press releases | Contact us
Copyright 2012 GSSM Pty Ltd | Privacy policy | Website Disclaimer | Sitemap Website Design : Cyrius Media Group